If you need to locate the table that contains the Lienar data for a Preventive Order => EAML_D_LFE_DATA-START_POINT and EAML_D_LFE_DATA-END_POINT
This info is extracted to BW via an exctractor 0PM_OM_OPA_1_EAML
You find the “linear data” record in the table EAML_D_LFE_DAT for a Functional Location by setting OBART=’IF’ and TABKEY = functional location (TPLNR)
You find the “linear data” record in the table EAML_D_LFE_DAT for a Maintenance Order by setting OBART=’OR’ and TABKEY = AUFNR